1.
Ultrasonics ; 118: 106564, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34530395

RESUMO

Tissue-Mimicking Material (TMM) is defined on IEC International Standards and applied in assessing ultrasonic diagnostic and therapeutic equipment's basic safety and essential performance. One of the TMM that fits IEC standards specification has its recipe described at IEC 60601-2-37, and it is fabricated using glycerol (11.21 %), deionized water (82.95%), benzalkonium chloride (0.47 %), silicon carbide (0.53 %), aluminum oxide 0.3 µm (0.88%), aluminum oxide 3.0 µm (0.94 %), and agar (3.08 %). Glycerol is the component responsible for adjusting the TMM's speed of sound. Moreover, it is recommended to store TMM in a closed container immersed in a mixture of water (88.1 %)/glycerol (11.9 %) to prevent it from drying out and avoiding air contact. The literature points out TMM measurements underwater can alter the speed of sound property as TMM tends to lose glycerol. Herein, the authors proposed to assess the viability of measuring the TMM speed of sound in the water/glycerol maintenance solution. First, the authors characterized the maintenance solution's speed of sound for a temperature range of 20 °C to 45 °C. Then, the group velocity of a set of TMM was measured underwater and in the maintenance solution for the same temperature range. The respective group velocity expanded uncertainty was calculated. The results indicate it is feasible to measure TMM in the maintenance solution, achieving group velocity values with no statistical difference from the ones measured underwater in the temperature range of 20 °C to 40 °C.


Assuntos
Materiais Biomiméticos , Imagens de Fantasmas/normas , Som , Terapia por Ultrassom/instrumentação , Ultrassonografia/instrumentação , Óxido de Alumínio , Compostos de Benzalcônio , Calibragem , Compostos Inorgânicos de Carbono , Segurança de Equipamentos , Glicerol , Compostos de Silício , Temperatura , Água
2.
Adv Sci (Weinh) ; 8(10): 2002178, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34026428

RESUMO

As a novel noninvasive therapeutic modality combining low-intensity ultrasound and sonosensitizers, sonodynamic therapy (SDT) is promising for clinical translation due to its high tissue-penetrating capability to treat deeper lesions intractable by photodynamic therapy (PDT), which suffers from the major limitation of low tissue penetration depth of light. The effectiveness and feasibility of SDT are regarded to rely on not only the development of stable and flexible SDT apparatus, but also the screening of sonosensitizers with good specificity and safety. To give an outlook of the development of SDT equipment, the key technologies are discussed according to five aspects including ultrasonic dose settings, sonosensitizer screening, tumor positioning, temperature monitoring, and reactive oxygen species (ROS) detection. In addition, some state-of-the-art SDT multifunctional equipment integrating diagnosis and treatment for accurate SDT are introduced. Further, an overview of the development of sonosensitizers is provided from small molecular sensitizers to nano/microenhanced sensitizers. Several types of nanomaterial-augmented SDT are in discussion, including porphyrin-based nanomaterials, porphyrin-like nanomaterials, inorganic nanomaterials, and organic-inorganic hybrid nanomaterials with different strategies to improve SDT therapeutic efficacy. There is no doubt that the rapid development and clinical translation of sonodynamic therapy will be promoted by advanced equipment, smart nanomaterial-based sonosensitizer, and multidisciplinary collaboration.


Assuntos
Antineoplásicos/uso terapêutico , Nanopartículas/uso terapêutico , Neoplasias/terapia , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos , Animais , Técnicas Biossensoriais/métodos , Terapia Combinada , Humanos , Neoplasias/metabolismo , Neoplasias/patologia , Espécies Reativas de Oxigênio/metabolismo
3.
Asian J Androl ; 23(6): 602-610, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33818526

RESUMO

Low-intensity pulsed ultrasound (LIPUS) is a promising therapy that has been increasingly explored in basic research and clinical applications. LIPUS is an appealing therapeutic option as it is a noninvasive treatment that has many advantages, including no risk of infection or tissue damage and no known adverse reactions. LIPUS has been shown to have many benefits including promotion of tissue healing, angiogenesis, and tissue regeneration; inhibition of inflammation and pain relief; and stimulation of cell proliferation and differentiation. The biophysical mechanisms of LIPUS remain unclear and the studies are ongoing. In recent years, more and more research has focused on the relationship between LIPUS and stem/progenitor cells. A comprehensive search of the PubMed and Embase databases to July 2020 was performed. LIPUS has many effects on stem cells. Studies show that LIPUS can stimulate stem cells in vitro; promote stem cell proliferation, differentiation, and migration; maintain stem cell activity; alleviate the problems of insufficient seed cell source, differentiation, and maturation; and circumvent the low efficiency of stem cell transplantation. The mechanisms involved in the effects of LIPUS are not fully understood, but the effects demonstrated in studies thus far have been favorable. Much additional research is needed before LIPUS can progress from basic science research to large-scale clinical dissemination and application.


Assuntos
Proliferação de Células , Células-Tronco/efeitos da radiação , Ondas Ultrassônicas , Humanos , Transdução de Sinais , Células-Tronco/fisiologia , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos
4.
Biomed Mater ; 16(3)2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33725684

RESUMO

The fast development of nanomedicine and nanobiotechnology has enabled the emerging of versatile therapeutic modalities with high therapeutic efficiency and biosafety, among which nanosonosensitizer-involved sonodynamic therapy (SDT) employs ultrasound (US) as the exogenous activation source for inducing the production of reactive oxygen species (ROS) and disease therapy. The chemoreactive nanosonosensitizers are the critical components participating in the SDT process, which generally determine the SDT efficiency and therapeutic outcome. Compared to the traditional and mostly explored organic sonosensitizers, the recently developed inorganic chemoreactive nanosonosensitizers feature the distinct high stability, multifunctionality and significantly different SDT mechanism. This review dominantly discusses and highlights two types of inorganic nanosensitizers in sonodynamic treatments of various diseases and their underlying therapeutic mechanism, including US-activated generation of electrons (e-) and holes (h+) for facilitating the following ROS production and delivery of organic molecular sonosensitizers. Especially, this review proposes four strategies aiming for augmenting the SDT efficiency on antitumor and antibacterial applications based on inorganic sonosensitizers, including defect engineering, novel metal coupling, increasing electric conductivity and alleviating tumor hypoxia. The encountered challenges and critical issues facing these inorganic nanosonosensitzers are also highlighted and discussed for advancing their clinical translations.


Assuntos
Nanomedicina/métodos , Nanopartículas/química , Neoplasias/terapia , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos , Animais , Biotecnologia/métodos , Linhagem Celular Tumoral , Sistemas de Liberação de Medicamentos , Elétrons , Humanos , Hipóxia , Nanotecnologia/métodos , Oxigênio/química , Engenharia de Proteínas/métodos , Espécies Reativas de Oxigênio , Semicondutores
5.
Ultrasonics ; 109: 106259, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33002831

RESUMO

An ultrasonic aspirator with elliptical vibration on the end face is presented in this paper. The ultrasonic vibration relied on a specially designed Langevin transducer. The end face of the transducer was screwed into a surgical tool capable of changing amplitude, which requires resonance to provide sufficient vibration amplitude for cutting cartilage or other biological tissues. Based on the coupling of two vertical bending vibrations, the new design produced the elliptical ultrasonic vibration on the end face of the surgical tool, which differed from the axial vibration of a traditional ultrasonic aspirator. The design greatly increased the mechanical effect of the aspirator. A specially designed blade was employed to remove the cartilage tissue. A prototype device was designed to operate at 20 kHz with a displacement amplitude of 150 µm at 200 V. The measurements of the vibrational and impedance responses showed the mechanical and electrical characteristics of the aspirator. Cutting tests on mice costal cartilage were subsequently conducted. Histological analysis displayed a higher proportion of live cells in the region around the cut site, which exhibited a higher removal efficiency.


Assuntos
Cartilagem/cirurgia , Sucção/instrumentação , Terapia por Ultrassom/instrumentação , Animais , Desenho de Equipamento , Camundongos , Ratos , Transdutores , Vibração
6.
Ultrasound Med Biol ; 47(2): 309-322, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33153807

RESUMO

Ultrasound and microbubble (USMB)-mediated drug delivery is a valuable tool for increasing the efficiency of the delivery of therapeutic agents to cancer while maintaining low systemic toxicity. Typically, selection of USMB drug delivery parameters used in current research settings are either based on previous studies described in the literature or optimized using tissue-mimicking phantoms. However, phantoms rarely mimic in vivo tumor environments, and the selection of parameters should be based on the application or experiment. In the following study, we optimized the therapeutic parameters of the ultrasound drug delivery system to achieve the most efficient in vivo drug delivery using fluorescent semiconducting polymer nanoparticles as a model nanocarrier. We illustrate that voltage, pulse repetition frequency and treatment time (i.e., number of ultrasound pulses per therapy area) delivered to the tumor can successfully be optimized in vivo to ensure effective delivery of the semiconducting polymer nanoparticles to models of hepatocellular carcinoma. The optimal in vivo parameters for USMB drug delivery in this study were 70 V (peak negative pressure = 3.4 MPa, mechanical index = 1.22), 1-Hz pulse repetition frequency and 100-s therapy time. USMB-mediated drug delivery using in vivo optimized ultrasound parameters caused an up to 2.2-fold (p < 0.01) increase in drug delivery to solid tumors compared with that using phantom-optimized ultrasound parameters.


Assuntos
Carcinoma Hepatocelular/tratamento farmacológico , Sistemas de Liberação de Medicamentos , Neoplasias Hepáticas/tratamento farmacológico , Microbolhas/uso terapêutico , Ondas Ultrassônicas , Animais , Calibragem , Carcinoma Hepatocelular/patologia , Modelos Animais de Doenças , Feminino , Fluorescência , Células Hep G2 , Humanos , Neoplasias Hepáticas/patologia , Camundongos , Necrose , Transplante de Neoplasias , Pontos Quânticos , Terapia por Ultrassom/instrumentação
7.
PLoS One ; 15(12): e0244020, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33320905

RESUMO

AIM: To assess the distribution and deposition of aerosols during simulated periodontal therapy. METHODS: A manikin with simulated fluorescein salivation was treated by four experienced dentists applying two different periodontal treatment options, i.e. air-polishing with an airflow device or ultrasonic scaling in the upper and lower anterior front for 5 minutes, respectively. Aerosol deposition was quantitatively measured on 21 pre-defined locations with varying distances to the manikins mouth in triplicates using absorbent filter papers. RESULTS: The selected periodontal interventions resulted in different contamination levels around the patient's mouth. The highest contamination could be measured on probes on the patient's chest and forehead but also on the practitioner's glove. With increasing distance to the working site contamination of the probes decreased with both devices. Air-polishing led to greater contamination than ultrasonic. CONCLUSION: Both devices showed contamination of the nearby structures, less contamination was detected when using the ultrasonic. Affirming the value of wearing protective equipment we support the need for universal barrier precautions and effective routine infection control in dental practice.


Assuntos
Aerossóis/química , Polimento Dentário/instrumentação , Controle de Infecções Dentárias/métodos , Periodontia/instrumentação , Terapia por Ultrassom/instrumentação , Humanos , Manequins , Segurança do Paciente , Equipamento de Proteção Individual/normas , Saliva/química
8.
Biosci Rep ; 40(9)2020 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-32936241

RESUMO

To investigate the alleviating effects of low-intensity pulsed ultrasound (LIPUS) on myelosuppression of Sprague-Dawley rats with breast cancer induced by cyclophosphamide (CTX). Breast cancer in rats was triggered by intragastric gavage with 7,12-dimethylbenz[a]anthracene (150 mg/kg). Then, the rats with breast cancer were randomly allocated to the LIPUS group (n=50) and the control group (n=50). The LIPUS group was injected intraperitoneally with CTX (50 mg/kg) for 4 consecutive days and underwent LIPUS treatment at femoral metaphysis 20 min per day from the first day of injection for 7 consecutive days. The control group was injected with CTX (50 mg/kg) and treated with LIPUS without energy output. Blood, enzyme-linked immunosorbent assay (ELISA), real-time quantitative polymerase chain reaction, Hematoxylin and Eosin (H&E) staining, and scanning electron microscopy were applied to detect the changes. The results indicated that LIPUS significantly promoted the proliferation of bone marrow nucleated cells, white blood cells (WBCs), IgA, IgG, and IgM in the peripheral blood (P<0.05) without the damage to liver and kidney function simultaneously. The mechanisms may result from the LIPUS alleviation effect on bone marrow hematopoietic function through regulating cytokines such as LIPUS can increase the expression of granulocyte colony-stimulating factor (G-CSF), stem cell factor, transforming growth factor-ß, and intercellular cell adhesion molecule-1, meanwhile LIPUS will decrease the expression of interleukin-6, tumor necrosis factor-α, and vascular cell adhesion molecule-1. LIPUS has potential to be a new adjuvant therapy method in clinic for ameliorating chemotherapy-induced myelosuppression.


Assuntos
Ciclofosfamida/efeitos adversos , Hematopoese/efeitos da radiação , Leucopenia/prevenção & controle , Neoplasias Mamárias Experimentais/tratamento farmacológico , Terapia por Ultrassom/métodos , 9,10-Dimetil-1,2-benzantraceno/administração & dosagem , 9,10-Dimetil-1,2-benzantraceno/toxicidade , Administração Oral , Animais , Contagem de Células Sanguíneas , Medula Óssea/efeitos dos fármacos , Medula Óssea/efeitos da radiação , Carcinógenos/administração & dosagem , Carcinógenos/toxicidade , Ciclofosfamida/administração & dosagem , Modelos Animais de Doenças , Feminino , Fêmur , Hematopoese/efeitos dos fármacos , Humanos , Injeções Intraperitoneais , Leucopenia/sangue , Leucopenia/induzido quimicamente , Leucopenia/diagnóstico , Neoplasias Mamárias Experimentais/induzido quimicamente , Ratos , Ratos Sprague-Dawley , Terapia por Ultrassom/instrumentação
9.
Niger J Clin Pract ; 23(9): 1237-1242, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32913162

RESUMO

AIMS: We evaluated and compared EndoActivator, CanalBrush, and passive ultrasonic irrigation (PUI) in the removal of calcium hydroxide and calcium hydroxide with iodoform and p-chlorophenol paste (Calcipast Forte) from artificial standardized grooves in the apical third of root canals. MATERIALS AND METHODS: A total of 34 mandibular premolars were prepared and then split longitudinally. A standardized groove was prepared in the apical part of both segments. The grooves were filled with either calcium hydroxide or Calcipast Forte, and the segments were reassembled. CanalBrush, EndoActivator, or PUI were used. The amount of remaining medicament was evaluated using a four-grade scoring system. RESULTS: None of the irrigation methods could completely remove the pastes from the grooves. More Calcipast Forte paste was detected compared with calcium hydroxide (P < 0.01). PUI was the least effective method in removing Calcipast Forte. CONCLUSIONS: It was more difficult to remove Calcipast Forte than a water-based calcium hydroxide paste.


Assuntos
Hidróxido de Cálcio/química , Clorofenóis , Cavidade Pulpar/patologia , Hidrocarbonetos Iodados , Materiais Restauradores do Canal Radicular/química , Irrigantes do Canal Radicular/administração & dosagem , Terapia por Ultrassom/métodos , Humanos , Irrigantes do Canal Radicular/química , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Irrigação Terapêutica/métodos , Terapia por Ultrassom/instrumentação , Ultrassom , Água
10.
Proc Natl Acad Sci U S A ; 117(29): 16848-16855, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32631991

RESUMO

In certain medical applications, transmitting an ultrasound beam through the skin to manipulate a solid object within the human body would be beneficial. Such applications include, for example, controlling an ingestible camera or expelling a kidney stone. In this paper, ultrasound beams of specific shapes were designed by numerical modeling and produced using a phased array. These beams were shown to levitate and electronically steer solid objects (3-mm-diameter glass spheres), along preprogrammed paths, in a water bath, and in the urinary bladders of live pigs. Deviation from the intended path was on average <10%. No injury was found on the bladder wall or intervening tissue.


Assuntos
Cálculos Renais/terapia , Terapia por Ultrassom/métodos , Ondas Ultrassônicas , Animais , Suínos , Transdutores , Terapia por Ultrassom/instrumentação
11.
Med Biol Eng Comput ; 58(6): 1325-1340, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32277340

RESUMO

The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulations on 3D anatomical models. Parametric studies in a generalized tissue model over dual-sectored ultrasound applicator configurations (acoustic surface intensities, lateral active acoustic output sector angles, and durations) were performed. Selected configurations and delivery strategies were applied on 3D pelvic anatomical models. Temperature and thermal dose distributions on the target region and surrounding tissues were calculated. Endovaginal cooling was explored as a strategy to mitigate vaginal heating. The 75-90° dual-sectored transurethral tubular transducer (3.5 mm outer diameter (OD), 14 mm length, 6.5 MHz, 8.8-10.2 W/cm2) and 2-3-min sonication duration were selected from the parametric study for acoustic and biothermal simulations on anatomical models. The transurethral applicator with two opposing 75-90° active lateral tubular sectors can create two heated volumes for a total of up to 1.8 cm3 over 60 EM43 °C, with at least 10 mm radial penetration depth, 1.2 mm urethral sparing, and no lethal damage to the vagina and adjacent bone (< 60 EM43 °C). Endovaginal cooling can be applied to further reduce the vaginal wall exposure (< 15 EM43 °C). Simulations on 3D anatomical models indicate that dual-sectored transurethral ultrasound applicators can selectively heat pelvic floor tissue lateral to the mid-urethra in short treatment durations, without damaging adjacent vaginal and bone tissues, as a potential alternative treatment option for stress urinary incontinence. Graphical abstract Schema for in silico investigation of transurethral ultrasound thermal therapy applicator for minimally invasive treatment of SUI.


Assuntos
Modelos Anatômicos , Terapia por Ultrassom/métodos , Incontinência Urinária por Estresse/terapia , Acústica , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética , Osso Púbico/anatomia & histologia , Osso Púbico/diagnóstico por imagem , Temperatura , Transdutores , Terapia por Ultrassom/instrumentação , Uretra/anatomia & histologia , Uretra/diagnóstico por imagem , Incontinência Urinária por Estresse/diagnóstico por imagem , Vagina/anatomia & histologia , Vagina/diagnóstico por imagem
12.
Hepatobiliary Pancreat Dis Int ; 19(5): 478-485, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32265136

RESUMO

BACKGROUND: Ultrasound-targeted microbubble destruction (UTMD) induces cellular inflow of drugs at low intensity, while high intensity eradicates tumor vessels. Since vascular endothelial growth factor receptor 2 (VEGFR2) is highly expressed in pancreatic ductal adenocarcinoma (PDAC), VEGFR2-targeted microbubble (MB) might additionally increase the tissue specificity of drugs and thus improve antitumor effects. In addition, fixing the dual pulse intensity could maximize MB properties. This study evaluated the one-off (experiment 1) and cumulative (experiment 2) treatment effect of UTMD by regulating the dual pulse output applied to PDAC using VEGFR2-targeted MB. METHODS: C57BL/6 mice inoculated with Pan-02 cells were allocated to five groups: VEGFR2-targeted MB+ gemcitabine (GEM), VEGFR2-targeted MB, non-targeted MB+GEM, GEM, and control groups. After injection of GEM or GEM and either VEGFR2-targeted or non-targeted MB, UTMD was applied for several minutes at low intensity followed by high intensity application. In experiment 1, mice were treated by the protocol described above and then euthanized immediately or at the tumor diameter doubling time (TDT). In experiment 2, the same protocol was repeated weekly and mice were euthanized at TDT regardless of protocol completion. Histological analysis by CD31 and VEGFR2 staining provided microvascular density (MVD) and VEGFR2 expression along vessels (VEGFR2v) or intra/peripheral cells (VEGFR2c). RESULTS: In experiment 1, TDT was significantly longer in the VEGFR2-targeted MB+GEM group compared to the non-targeted MB+GEM, GEM, and control groups, while the VEGFR2-targeted MB group showed no statistical significance. MVD and VEGFR2v in the immediate euthanasia was significantly lower in the VEGFR2-targeted MB+GEM and VEGFR2-targeted MB groups than other conditions. In experiment 2, the VEGFR2-targeted MB+GEM group produced significantly longer TDT than the GEM or control groups, whereas the VEGFR2-targeted MB group showed no significant difference. Histology revealed significantly reduced VEGFR2v and VEGFR2c in the VEGFR2-targeted and non-targeted MB+GEM groups, while only VEGFR2v was significantly less in the VEGFR2-targeted MB group. CONCLUSIONS: UTMD-mediated GEM therapy with the dual pulse application using VEGFR2-targeted MB substantially suppresses PDCA growth.


Assuntos
Antimetabólitos Antineoplásicos/farmacologia , Carcinoma Ductal Pancreático/terapia , Desoxicitidina/análogos & derivados , Endossonografia , Microbolhas , Neoplasias Pancreáticas/terapia , Terapia por Ultrassom/instrumentação , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Animais , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/metabolismo , Carcinoma Ductal Pancreático/patologia , Linhagem Celular Tumoral , Meios de Contraste , Desoxicitidina/farmacologia , Feminino , Compostos Férricos , Ferro , Camundongos Endogâmicos C57BL , Óxidos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Carga Tumoral/efeitos dos fármacos , Gencitabina
13.
Artigo em Inglês | MEDLINE | ID: mdl-32149634

RESUMO

A two-dimensional (2-D) array with a small pitch (approximately 0.5λ in medium) can achieve complete 3-D control of ultrasound beams without grating lobes and enable the generation of multiple focal spots simultaneously, which is a desired tool for noninvasive therapy. However, the large electrical impedance of 2-D array elements owing to their small size results in a low energy transfer efficiency between a 2-D array and an electrical system, thereby limiting their practical applications. This article presents the development of a 1-MHz 256-element 2-D array ultrasonic transducer of low electrical impedance based on a new Sm-doped Pb(Mg1/3Nb2/3)O3-PbTiO3 (Sm-PMN-PT) piezoceramic with ultrahigh dielectric permittivity. The electrical impedance of the array element is decreased by 3.4 times as the Sm-PMN-PT replacing commercial PZT-5H. Consequently, the output acoustic pressure of the 2-D array made of Sm-PMN-PT ceramic is approximately twice that of the 2-D array made of PZT-5H ceramic under the same excitation conditions. Array elements are spaced at a 1.1-mm pitch ( 0.71λ in water), enabling a large steering range of the ultrasound beam. A multiple-target blood-brain barrier opening in vivo is demonstrated using the proposed 2-D array with electronic focusing and steering. The obtained results indicate that the 2-D array made of Sm-PMN-PT ceramic is promising for practical use in low-intensity ultrasound therapy applications.


Assuntos
Cerâmica/química , Metais/química , Transdutores , Terapia por Ultrassom/instrumentação , Animais , Barreira Hematoencefálica/efeitos da radiação , Encéfalo/efeitos da radiação , Desenho de Equipamento , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Crânio/fisiologia
14.
J Cosmet Dermatol ; 19(4): 850-854, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32011076

RESUMO

BACKGROUND: Intense focused ultrasound (IFUS) is a Nonablative skin tightening technology with good safety profile, but limited efficacy. Most clinical studies have been performed to evaluate the efficacy of the Ulthera IFUS (Ulthera, Mesa, AZ) in treating redundant skin. OBJECTIVE: To report our experience with Doublo IFUS (Doublo™, HIRONIC Co.) for treating neck and lower face laxity. METHODS: This is a prospective study of 43 patients with neck and lower facial laxity treated using IFUS. Response was assessed by two independent dermatologists and graded on a scale of 0 (exacerbation) to 5 (75%-100% improvement). Patient's level of "sagging" and "volume loss", satisfaction and tolerance were documented. RESULTS: Nine subjects (52.9%) mentioned some improvement. Erythema and edema were acute and transient responses. CONCLUSION: Ultrasound appears to be a safe modality for facial skin tightening in selected patients with minor skin sagging and no volume discrepancy.


Assuntos
Técnicas Cosméticas/instrumentação , Envelhecimento da Pele/efeitos da radiação , Pele/efeitos da radiação , Terapia por Ultrassom/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas Cosméticas/efeitos adversos , Edema/epidemiologia , Edema/etiologia , Eritema/epidemiologia , Eritema/etiologia , Face , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Satisfação do Paciente , Seleção de Pacientes , Estudos Prospectivos , Rejuvenescimento , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Adulto Jovem
15.
Artigo em Inglês | MEDLINE | ID: mdl-32086207

RESUMO

Piezoelectricity in bone is thought to be a mechanism by which ultrasound promotes the healing of bone fractures. However, a few studies have been conducted in the more clinically relevant megahertz range. To understand the piezoelectricity in bone, we fabricated ultrasound transducers using bone samples as piezoelectric materials and identified the longitudinal ultrasound radiation and reception in the megahertz range. The maximum transmitting sensitivity of the bone transducer was 140 mPa/V, which was nearly 1/1000 of a polyvinylidene difluoride (PVDF) transducer that has better electrical properties and piezoelectricity. The resonance frequencies of the transducer depend on the plate thickness and angle between the bone axis (alignment direction of the hydroxyapatite crystallites) and ultrasound propagation direction, reflecting the anisotropic character of the bone. The reception and transmission sensitivities of the bone transducers also depend on the plate thickness and angle, showing maximum values at off-axis angles. These results indicate the existence of both piezoelectricity and inverse piezoelectricity in bone, which may be key factors in understanding the bone healing by low-intensity biophysical (electrical or mechanical) stimulation.


Assuntos
Osso e Ossos , Terapia por Ultrassom , Animais , Osso e Ossos/fisiologia , Osso e Ossos/efeitos da radiação , Bovinos , Transdutores , Terapia por Ultrassom/instrumentação , Terapia por Ultrassom/métodos
16.
Ann Vasc Surg ; 66: 479-485, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31917220

RESUMO

BACKGROUND: Ultrasound-enhanced catheter-directed thrombolysis (UET) using the Ekosonic® Endovascular System device for acute, peripheral arterial ischemia has been purported in clinical trials to accelerate the fibrinolytic process to reduce treatment time and lytic dosage. We aim to describe outcomes of UET in a real-world clinical setting. METHODS: We performed a retrospective review of all patients undergoing UET for acute limb ischemia at a single institution. Data collected included patient demographics, procedural details, and 30-day and 1-year outcomes. The primary endpoints for analysis were major adverse limb events (MALEs; reintervention and/or amputation) and mortality within 30-days and 1-year. Secondary endpoints included technical success, use of adjunctive therapies, and postoperative complications. RESULTS: A total of 32 patients (mean age 67.4 ± 14.9 years; 25% women) underwent UET for acute limb ischemia between 2014 and 2018. The Rutherford Acute Limb Ischemia Classification was Rutherford (R) 1 in 56.3%, R2a in 31.3%, and R2b in 12.5%. Etiology was thrombosis of native artery in 12.5% of patients, prosthetic bypass in 31.3%, autogenous bypass in 6.3%, and stented native vessel in 50.0%. Mean duration of thrombolytic therapy was 22.2 ± 11.3 hr, and mean tissue plasminogen activator dose was 24.5 ± 15.3 mg. MALEs occurred in 16.7% of patients within the first 30 days and 38.9% experienced a MALE by 1 year. Limb salvage at 30 days and 1 year was 93.8% and 87.5%, respectively. Ipsilateral reintervention was required in 12.5% of patients within 30 days and 37.5% of patients within 1 year. Overall mortality was 6.2% at 30 days and 13.5% at 1 year. In-line flow to the foot was re-established in 90.6% of patients, with a significant improvement in preoperative to postoperative ankle-brachial index (0.31 ± 0.29 vs. 0.78 ± 0.34, P < 0.001) and number of patent tibial runoff vessels (1.31 ± 1.20 vs. 1.96 ± 0.86, P < 0.001). There was no significant difference in revascularization success between occluded vessel types. All but one patient required adjunctive therapy such as further thromboaspiration, stenting, or balloon angioplasty. Major bleeding complications occurred in 3 patients (9.4%), including 1 intracranial hemorrhage (3.1%). CONCLUSIONS: UET with the EKOS device demonstrates acceptable real-world outcomes in the treatment of acute limb ischemia. UET is generally safe and effective at re-establishing in-line flow to yield high limb salvage rates. However, UET is associated with a high rate of reintervention. Further investigation is needed into specific predictors of limb salvage and need for reintervention, as well as cost-efficacy of this technology compared with that of traditional methods.


Assuntos
Cateterismo Periférico/instrumentação , Fibrinolíticos/administração & dosagem , Isquemia/terapia , Doença Arterial Periférica/terapia , Terapia Trombolítica , Terapia por Ultrassom/instrumentação , Dispositivos de Acesso Vascular , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Desenho de Equipamento , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Isquemia/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Terapia Trombolítica/efeitos adversos , Terapia Trombolítica/mortalidade , Fatores de Tempo , Resultado do Tratamento , Terapia por Ultrassom/efeitos adversos , Terapia por Ultrassom/mortalidade , Grau de Desobstrução Vascular
17.
Photobiomodul Photomed Laser Surg ; 38(3): 181-185, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31944884

RESUMO

Objective: The topography of the root surface plays an important role in plaque accumulation, cell adhesion, and periodontal healing. The aim of this study is to profilometrically evaluate the root surface changes following the instrumentation using different tools. Methods: Forty dentin blocks of buccal and lingual root surfaces were obtained from 20 single-rooted periodontally diseased hopeless teeth and randomly divided into 4 groups. Each group was subjected to different root instrumentation tools such as stainless steel (SS) Gracey curette (Group 1); titanium nitride (TIN) Gracey curette (Group 2); ultrasonic piezoelectric device with a special tip designed for root surfaces (H3) (Group 3); and Er:YAG laser (Er:YAG tip) chisel (Group 4). A calibrated clinician instrumented all surfaces in each group. The root surfaces were profilometrically evaluated before and after instrumentations. Results: There were no statistical differences between the initial roughness levels of the groups. TIN curettes revealed the most prominent effect on smoothing the surface, whereas the Er:YAG tip showed the highest roughness in comparison with the other root surface instrumentation tools. Conclusions: Considering the importance of root surface roughness after treatment for the success of periodontal therapy, the TIN curette was the most periodontally appealing tool followed by H3, SS curette, and Er:YAG tip.


Assuntos
Raspagem Dentária/instrumentação , Doenças Periodontais/terapia , Raiz Dentária/ultraestrutura , Curetagem/instrumentação , Humanos , Técnicas In Vitro , Lasers de Estado Sólido , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Titânio , Terapia por Ultrassom/instrumentação
18.
Curr Opin Urol ; 30(2): 149-156, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31905177

RESUMO

PURPOSE OF REVIEW: Burst wave lithotripsy and ultrasonic propulsion of kidney stones are novel, noninvasive emerging technologies to separately or synergistically fragment and reposition stones in an office setting. The purpose of this review is to discuss the latest refinements in technology, to update on testing of safety and efficacy, and to review future applications. RECENT FINDINGS: Burst wave lithotripsy produced consistent, small passable fragments through transcutaneous applications in a porcine model, while producing minimal injury and clinical trials are now underway. A more efficient ultrasonic propulsion design that can also deliver burst wave lithotripsy effectively repositioned 95% of stones in 18 human participants (18 of 19 kidneys) and clinical trials continue. Acoustic tractor beam technology is an emerging technology with promising clinical applications through the manipulation of macroscopic objects. SUMMARY: The goal of the reviewed work is an office-based system to image, fragment, and reposition urinary stones to facilitate their natural passage. The review highlights progress in establishing safety, effectiveness, and clinical benefit of these new technologies. The work is also anticipating challenges in clinical trials and developing the next generation of technology to improve on the technology as it is being commercialized today.


Assuntos
Litotripsia/métodos , Terapia por Ultrassom/métodos , Cálculos Urinários/cirurgia , Acústica , Animais , Modelos Animais de Doenças , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Litotripsia/instrumentação , Litotripsia/tendências , Litotripsia a Laser , Suínos , Terapia por Ultrassom/instrumentação , Ultrassonografia , Ureteroscopia , Cálculos Urinários/diagnóstico por imagem
19.
Artigo em Inglês | MEDLINE | ID: mdl-31976885

RESUMO

Cavitation events generated during histotripsy therapy generate large acoustic cavitation emission (ACE) signals that can be detected through the skull. This article investigates the feasibility of using these ACE signals, acquired using the elements of a 500-kHz, 256-element hemispherical histotripsy transducer as receivers, to localize and map the cavitation activity in real time through the human skullcap during transcranial histotripsy therapy. The locations of the generated cavitation events predicted using the ACE feedback signals in this study were found to be accurate to within <1.5 mm of the centers of masses detected by optical imaging and found to lie to within the measured volumes of the generated cavitation events in >~80 % of cases. Localization results were observed to be biased in the prefocal direction of the histotripsy array and toward its transverse origin but were only weakly affected by focal steering location. The choice of skullcap and treatment pulse repetition frequency (PRF) were both observed to affect the accuracy of the localization results in the low PRF regime (1-10 Hz), but the localization accuracy was seen to stabilize at higher PRFs (≥10 Hz). Tests of the localization algorithm in vitro, for treatment delivered to a bovine brain sample mounted within the skullcap, revealed good agreement between the ACE feedback-generated treatment map and the morphological characteristics of the treated volume of the brain sample. Localization during experiments was achieved in real time for pulses delivered at rates up to 70 Hz, but benchmark tests indicate that the localization algorithm is scalable, indicating that higher rates are possible with more powerful hardware. The results of this article demonstrate the feasibility of using ACE feedback signals to localize and map transcranially generated cavitation events during histotripsy. Such capability has the potential to greatly simplify transcranial histotripsy treatments, as it may provide a non-MRI-based method for monitoring and localizing transcranial histotripsy treatments in real time.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Terapia por Ultrassom/métodos , Ultrassonografia , Algoritmos , Animais , Bovinos , Retroalimentação , Transdutores , Terapia por Ultrassom/instrumentação
20.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31594557

RESUMO

INTRODUCTION: Surgical techniques for extirpation of tumours of the parotid gland have evolved significantly in recent years. Previous data suggest the use of Harmonic Scalpel reduced operative time, intraoperative blood loss, postoperative drain production, and incidence of facial nerve injury, in comparison to cold scalpel dissection MATERIAL AND METHODS: retrospective analysis of 2group of patients operated using harmonic scalpel versus cold knife dissection and bipolar diathermy and compare operative time and post-surgical complication rate:, facial nerve injury, sialocele or salivary fístula formation, after parotidectomy for benign parotid tumours. RESULTS: 108 patients were included. Regarding surgical time, the mean time to using Harmonic Scalpel was 114±39 (Min: 60/Max: 240), and the mean time using bipolar diathermy was 135±38 (Min: 90/Max: 285) and this was the only significant difference between the 2techniques (p=.049). CONCLUSIONS: Harmonic scalpel is a safe and effective tool to perform parotid surgery in benign tumours. However, a shorter surgical time was the only advantage found over the traditional cold dissection and bipolar dissection method.


Assuntos
Diatermia/métodos , Dissecação/métodos , Neoplasias Parotídeas/cirurgia , Instrumentos Cirúrgicos , Terapia por Ultrassom/instrumentação , Adenolinfoma/cirurgia , Adenoma Pleomorfo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diatermia/efeitos adversos , Dissecação/efeitos adversos , Dissecação/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Terapia por Ultrassom/métodos , Adulto Jovem